72.5kV Inductive Voltage Transformer

Home Technical

72.5kV Inductive Voltage Transformer (IVT), also known as a Potential Transformer (PT) or Voltage Transformer (VT), is a high-voltage instrument transformer designed to accurately reduce system voltages up to 72.5 kV to standardized low-voltage values for metering, protection, monitoring, and control. It provides electrical isolation between the high-voltage power network and secondary equipment, ensuring both measurement accuracy and operator safety.

 

Working Principle

 

A 72.5kV inductive voltage transformer operates based on the principle of electromagnetic induction. The primary winding is connected across the high-voltage system, inducing a proportional voltage in the secondary winding according to the turns ratio.

 

Main Components

·High-voltage primary winding

·One or more secondary windings (metering and protection)

·Laminated silicon steel magnetic core

·Oil-paper or SF6-free insulation system (depending on design)

·Porcelain or composite silicone rubber insulator housing

·Primary high-voltage terminal

·Secondary terminal box

·Earthing terminal

·Pressure relief device (oil-filled designs)

·Mounting base

 

Typical Technical Specifications

·Highest System Voltage: 72.5 kV

·Rated Primary Voltage: 66 kV or 69 kV

·Rated Secondary Voltage: 100 V, 110 V, 100/√3 V, 110/√3 V

·Frequency: 50 Hz / 60 Hz

·Accuracy Class: 0.1, 0.2, 0.5, 3P, 6P

·Rated Burden: 25–200 VA

·Rated Voltage Factor: 1.2 continuous, 1.5 for 30 s or per standard

·Insulation Level: 140/325 kV (Typical)

·Cooling: Natural Oil-Air (ONAN) or Dry Type

·Installation: Outdoor

 

Applications

A 72.5kV inductive voltage transformer is commonly used in:

·Transmission substations

·Distribution substations

·Utility switching stations

·Industrial substations

·Renewable energy substations

·Wind farms

·Solar power plants

·High-voltage switchyards

 

Advantages

·High measurement accuracy

·Excellent dielectric insulation

·Reliable long-term operation

·Strong resistance to environmental conditions

·Low maintenance requirements

·High mechanical strength

·Suitable for both metering and protective relaying

 

Typical Secondary Outputs

Common secondary voltages include:

·100 V

·110 V

·100/√3 V

·110/√3 V

 

These outputs are used with:

·Revenue energy meters

·Protective relays

·Synchronizing equipment

·SCADA systems

·Power quality analyzers

·Digital fault recorders

 

Common Standards

A 72.5kV inductive voltage transformer is generally designed and tested in accordance with:

·IEC 61869-3 – Instrument Transformers – Additional requirements for Inductive Voltage Transformers

·IEC 61869-1 – General requirements

·IEEE C57.13 – IEEE Standard Requirements for Instrument Transformers

·IEC 60044-2 (legacy standard, superseded by IEC 61869)

 

Typical Applications in a 72.5kV Substation

·Busbar voltage measurement

·Transmission line voltage monitoring

·Revenue metering

·Distance and overvoltage protection

·Synchronizing and auto-reclosing

·SCADA and remote monitoring

·Fault recording

·Power quality monitoring

 

A 72.5kV Inductive Voltage Transformer is an essential component in high-voltage substations, providing a precise, isolated, and scaled representation of system voltage for reliable metering, protection, automation, and control while ensuring safe operation of secondary equipment.